FRENIC-Ace

Customizable logic function is available as a standard feature. FRENIC-Ace has built-in customizable logic functions with a maximum of 200 steps including both digital and analog operation functions, giving customers the ability to customize their inverters—from simple logic functions to full-scale programming. Fuji Electric also has plans to offer programming templates for wire drawing machines, hoists, spinning machines, and other applications so that the FRENIC-Ace can be used as a dedicated purpose inverter.

FRENIC-Ace has readily available interface cards and various types of fieldbus / network to maximize its flexibility.

  • Sensorless dynamic torque vector control
  • Motor vector control with PG (with optional card)
  • Synchronous motor with sensorless vector control
  • 2-channel on-board RS485 communications port
  • Standard CANopen compatibility
  • Removable keypad device
  • Removable control terminal block board

FRENIC-Ace has two different multi-function keypads available

  • Multi-function keypad with LCD display: Enhanced HMI functionality
  • USB keypad: Connect to a computer for more efficient operation (set-up, troubleshooting, maintenance, etc)

FRENIC-Ace is equipped with STO functional safety function as a standard. Therefore output circuit magnetic contactors are not required for safe stop implementation. Enhanced standard features position FRENIC-Ace ahead of its class (Safety input: 2CH, output: 1CH).

Complies with (coming soon)

Option Installation type
RS485 communications card
PG interface (5V) card
PG interface (12/15V) card
DeviceNet communication card
CC-Link communication card
PROFIBUS-DP communication card (Coming Soon)
EtherNet/IP communication card (Coming Soon)
ProfiNet-RT communication card (Coming Soon)
CANopen communication card (Coming Soon)
Digital input/output interface card
Analog input/output interface card
EN ISO 13849-1: 2008, Cat.3 / PL=e IEC/EN 61800-5-2: 2007 SIL3 (Safety feature: STO)
IEC/EN 60204-1: 2005/2006 Stop category 0 IEC/EN 62061: 2005 SIL3
IEC/EN 61508-1 to -7: 2010 SIL3  

FRENIC-Ace components have a design life of ten years.
A longer maintenance cycle also helps to reduce running costs.

Design life Main circuit capacitor 10 years*
Electrolytic capacitors on PCB 10 years*
Cooling fan 10 years*
Life conditions Ambient temperature +40°C
Load rate 100% (HHD specifications)
80% (HND/HD/ND specifications)

* ND specifications have a rated current of two sizes higher than HHD specifications, so the life is 7 years.

Standards

RoHS Directive

Standard compliance with European regulations that limit the use of specific hazardous substances (RoHS)

<Six hazardous substances> Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), polybrominated biphenyl ether (PBDE)
<About RoHS> Directive 2002/95/EC, issued by the European Parliament and European Council, limits the use of specific hazardous substances in electrical and electronic devices.

Global compliance

Standard compliance

Driver Centre’ was established in the year of 1986, at Chennai, Tamil Nadu. We offer complete installation services and hardware and software support to our clients. We are globally recognized as the prominent supplier and trader of premium quality drive and speed control systems.